Informações Legal

When you visit any website, it may store or retrieve information on your browser, mostly in the form of 'cookies'. This information, which might be about you, your preferences, or your internet device (computer, tablet or mobile), is mostly used to make the site work as you expect it to. You can find out more about how we use cookies on this site, and prevent the setting of non-essential cookies, by clicking on the different category headings below. However, if you do this then it may impact your experience of the site and the services we are able to offer.

Catálogo e lista de preços

Catalogues

ZEMAN catalogue EUR - Open
ZEMAN catalogue USD - Open

Price list

ZEMAN price list EUR - Open
ZEMAN price list USD - Open

Informação

Produtos visualizados

EET

Podle zákona o evidenci tržeb je prodávající povinen vystavit kupujícímu účtenku. Zároveň je povinen zaevidovat přijatou tržbu u správce daně online; v případě technického výpadku pak nejpozději do 48 hodin. Tato povinnost se v současné době vztahuje pouze na některé typy plateb, zejména platby on-line převodem.
DUNLOP® Boots for Pross

KAN ZEMAN TK09FM01KH capô não inflamável

Novo produto

Hood Style TK09FM01-FM02

Mais detalhes

3 Itens

Produto imediatamente disponível

Aviso: Últimos itens disponíveis!

Ao comprar este produto pode ganhar até 1 ponto de fidelização. Seu carrinho totalizará 1 ponto de fidelização que podem ser convertidos num vale de desconto de € 0.30.


€ 10.23

  No tax

-50%

€ 20.46

  • Único tamanho

Adicionar à Lista de desejos

Free Google QRcode module from Mediacom87

Ficha informativa

PadrãoEN 13911:2004, EN 340:2004

Mais informação

Hood Style TK09FM01-FM02

Certification: 

EN 13911:2004, EN 340:2004

Description

Weight: 230g/m2

Weave: Knit

Color: Dark Blue, Black, Gray, Light Brown, Greyish White

Construction: Double layer hood

Size: One size fits to all - UNI

Functions

Flame spread: 

  • No flaming to edge
  • No hole formation
  • No molten debris
  • No afterflame & after glow

Heat transfer

Flame:

  • HTI24 > 15s
  • HTI24-12 > 5s

Radiation

t24 > 28s

t24-12 > 5s

Residual strength

> 2800 kPA

Heat resistance

< 1,5 %

Seam breaking strength

> 1650 kPA

Limitation of use:

Before using this the hood, the hazard which is happening must be subject to an incident - specifics risk assessment by teh user. Teh fire hood DOES NOT protect from the following risk:

  • Fire entry or activities with the equivalent fire-contact risk
  • Chemical risk
  • Contact with bulk flammable liquid fires

Guarantee

Quaranteed flame resistance materials for the life of the hood